Insituform® CIPP Technical Envelope

survey_truck.jpg
Diameter Range 15 – 244 cm
pH Range .5 - 10.5
Effluent Temperature up to 60° c
Pipe Condition - Fully Deteriorated Yes
Pipe Condition - Partially Deteriorated Yes
Bends Yes
Offset Joints Yes
Diameter Changes Yes, without manhole access
Thickness Changes Yes, without manhole access
Typical Shot Length 61 – 305 m
Host Pipe Shape All Shapes
Host Pipe Material All Materials


men_insititruck.jpgThe table refers to general purpose municipal sewer CIPP projects. Insituform® can provide products that extend beyond these parameters through our engineering group. Please click on “Ask an Expert” for assistance with applications extending beyond this technical envelope.

Click here to view Insituform CIPP brochure.