Insituform® CIPP Technical Envelope
| Diameter Range |
15 – 244 cm |
|
| pH Range |
.5 - 10.5 |
|
| Effluent Temperature |
up to 60° c |
|
| Pipe Condition - Fully Deteriorated |
Yes |
|
| Pipe Condition - Partially Deteriorated |
Yes |
|
| Bends |
Yes |
|
| Offset Joints |
Yes |
|
| Diameter Changes |
Yes, without manhole access |
| Thickness Changes |
Yes, without manhole access |
| Typical Shot Length |
61 – 305 m |
|
| Host Pipe Shape |
All Shapes |
|
| Host Pipe Material |
All Materials |
|
The table refers to general purpose municipal sewer CIPP projects. Insituform® can provide products that extend beyond these parameters through our engineering group. Please click on “Ask an Expert” for assistance with applications extending beyond this technical envelope.
Click here to view Insituform CIPP brochure.
|